HUATEC GROUP CORPORATION

HUATEC GROUP CORPORATION
Professional Testing Equipments:Ultrasonic Flaw Detector

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMagnetic Particle Testing

Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop

Certification
China HUATEC GROUP CORPORATION certification
China HUATEC GROUP CORPORATION certification
Customer Reviews
huatec hardness tester, very good quality,we are very satisfied with the portable hardness tester RHL-50. Kumaren Govender Sotuth Africa

—— Kumaren Govender

I'm Online Chat Now

Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop

Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop
Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop

Large Image :  Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop

Product Details:

Place of Origin: Beijing
Brand Name: HUATEC
Certification: ISO, CE, GOST
Model Number: HCDX-10000

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Packaging Details: Standard export package
Delivery Time: 1-4days
Payment Terms: T/T, Paypal, Western Union
Supply Ability: 500pcs per month
Detailed Product Description
Fluorescent Magnetic Powder: 2-3 G / L, Odorless Kerosene Defoaming Agent: 0.5 - 1 Grams / Liter
Dispersant: 0.2%, Check The Weight Of The Liquid Rust Inhibitor: 0.5%, Check The Weight Of Liquid
Residual Magnetism Method: I=20D ~ 40D Continuous Method: I=8D To 15D
High Light:

mt test specimen

,

magnetic strenght meter

Model HCDX-10000  Magnetic Particle inspection Equipment

 

 

1. Equipment composition

Control center (including operation panel, control panel and main power board etc.)

Control system (SIEMENS)

Main engine (including clamping mechanism, magnetization mechanism, electrode mechanism, etc.)

Magnetic suspension spray system

Darkroom system

Coil movement device

Clamping and rotating mechanism

Bracket rotating mechanism

 

2. Inspection workpiece:

 

Shaft specification:

Workpiece rotation diameter of less than 400mm, within a length of 2000mm

 

3. Equipment capacity:

Running time: more than 500 hours / month

 

4. Local design standards:

 

JB/T8290 - 1998 "magnetic particle flaw detector"

 

5. Main technical indexes

Circumferential magnetization current AC:0 - 10000A FWDC, continuous adjustable, with power off phase control

Longitudinal magnetization magnetic potential AC:0 - 16000AT, continuous adjustable, with power off phase control.

Electrode spacing: 200 - 2500mm.

Magnetization method: direct pass method, coil method.

Magnetization mode: three kinds of circumferential magnetization, longitudinal magnetization and compound magnetization can be flexibly chosen.

The use of the environment: - 10 C and C +40, relative humidity is less than 90%.

Storage environment: temperature of - 20 C and 60 C, relative humidity is less than 70%. Non corrosive

Gas dust and high frequency electromagnetic pollution.

Sensitivity test: according to the People's Republic of China machinery industry standard JB/T6065 - 92, "magnetic powder testing standard test film", AII, test piece display clear. And standard DIN EN ISO 9934.

Power supply: three-phase four wire, 380V + 10%, 50HZ, about 600A.

Inspection surface: all surface cracks and other defects.

Demagnetization AC: automatic attenuation type demagnetization.

Demagnetization; DC:; ultra low frequency demagnetization

Remanence: the maximum remanent magnetization after demagnetization is less than 0.3mT

Workpiece rotation speed: 4-6rpm. (large workpiece bracket rotating, small workpiece clamping rotation)

Magnetization coil: inner diameter 400mm. The coil moves in an electric way.

Pneumatic clamping: clamping stroke 0-75mm.

Air pressure: 0.4 - 0.8MP.

Power control cabinet: 900 (width) * 1200 (long) * 2000 (high) mm.

Test bed (including UV lamp): 1000 (width) * 3500 (long) * 2100 (high) mm.

Temporary loading rate: less than 20%

 

6. Running program: manual and automatic

 

The automatic program is: clamping - liquid - magnetization - rotation observation (clamping and bracket rotation two) - demagnetization - loose clamp, the whole process is controlled by small industrial PLC (long workpiece, subsection magnetization)

 

7. Control center

 

The control center is based on programmable logic controller (PLC). Control cabinet as the main body, contains a variety of actuators, magnetization trigger circuit, the main transformer

8. Host

The host is composed of main body, stainless steel tank, longitudinal magnetization, coil to weeks of moving mechanism, carrier rotating mechanism, sprinkler system, rail, pneumatic mechanism and circumferential and longitudinal main transformer

Model HCDX-10000 Magnetic Particle Inspection Equipment For Lab / Workshop 0

Figure 2, each part of the equipment

Body: horizontal sheet metal structure, making use of the high quality material of the equipment.

Stainless steel collection tank: made of 1.5mm stainless steel.

Longitudinal magnetizer: consisting of coils.

The circumferential magnetizer consists of two electrically connected electrode plates and an electrode shaft.

Suspension system of magnetic suspension: the injection quantity can be adjusted by moving the valve. With stirring device antimagnetic precipitation powder. The circuit is provided with a filter convenient for replacing.

Rail: for supporting and moving coil and mobile electrode.

Electrode box: welded by 10mm steel plate.

Rotating mechanism: by the speed reduction motor through the chain transmission mechanism, the transmission roller to drive the workpiece Rotate or clamp workpiece rotation.

Coil movement mechanism: consisting of a gear rack mechanism.

The pneumatic mechanism consists of a cylinder, solenoid valve, control valve, air source treatment components, used for clamping, has Xiangtong electromagnetic, ensure the detection sensitivity.

9.Lighting

Equipped with white light and UV light system. The intensity of UV irradiation is up to standard

10.Others

An operating panel for mobile operation is installed on the host computer.

The device is installed on the ground without the equipment foundation.

Grease is butter.

Install the muffler on the solenoid valve.

Install air handling triple parts.

Use a limit switch with excellent heat and dust resistance.

The wires are wired at both ends

11.Features and functions

Compound magnetization solves the problem that once the workpiece is magnetized in all directions without missing.

The main circuit is contactless control, and the equipment is stable.

The flaw detector adopts PLC centralized control.

This machine adopts low voltage high current output current, ampere, adjustable.

The working principle of overview: This machine with programmable logic controller (PLC) as the core, according to the detection process, send information by the sensor, after PLC treatment, were judged to control mechanical action related, according to set parameters, week longitudinal magnetization, using special thyristor phase-shift trigger integrated circuit to control the circumferential and longitudinal silicon controlled trigger circuit. Output trigger pulse

Characteristic:

Through touch screen input, storage, detection process, rapid call detection process.

Part counter.

Over current and under current sound and light alarm.

Clamping function for both hands safety control.

Magnetizing current and phase difference of 120 Eve joy.

The electrode has a copper pad against sparking.

12.Business conditions

1. User owned

(1) power supply: supply a designated place (a place), 380V, 50HZ, > 250A.

(2) air source: supply a designated place (one) greater than 0.4Mpa.

2. delivery date

(1) 60 working days after ordering, to the design, manufacture and inspection of the factory.

 

13. Selection of magnetizing current

The circumferential magnetization current can generally be calculated in the lower order

Continuous method: I=8D to 15D

Residual magnetism method: I=20D ~ 40D

I was in the current value of A

D - specimen diameter or maximum width (mm)

The above values are the reference values, and the actual work values shall be determined by the sensitivity test.

14. Magnetic suspension configuration:

Preparation of magnetic suspension of water agent:

Fluorescent magnetic powder: 2-3 g / liter

Dispersant: 0.2%, check the weight of the liquid

Rust inhibitor: 0.5%, check the weight of liquid

Defoaming agent: 0.5 - 1 grams / liter

Preparation of magnetic suspension for oil

(use odorless kerosene = 96 DEG C, flash point)

Fluorescent magnetic powder: 2-3 g / L, odorless kerosene

Dispersant: 0.2%, check the weight of the liquid