HUATEC GROUP CORPORATION

HUATEC GROUP CORPORATION
Professional Testing Equipments:Ultrasonic Flaw Detector

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMagnetic Particle Testing

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter

Certification
China HUATEC GROUP CORPORATION certification
China HUATEC GROUP CORPORATION certification
Customer Reviews
huatec hardness tester, very good quality,we are very satisfied with the portable hardness tester RHL-50. Kumaren Govender Sotuth Africa

—— Kumaren Govender

I'm Online Chat Now

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter
Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter

Large Image :  Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter

Product Details:

Place of Origin: Beijing
Brand Name: HUATEC
Certification: ISO, CE, GOST
Model Number: HGS-10C

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Packaging Details: Standard export package
Delivery Time: 1-4days
Payment Terms: T/T, Paypal, Western Union
Supply Ability: 500pcs per month
Detailed Product Description
Testing Range: 0~200m T~2000mT Accuracy: ±5%
Sensitivity: 0.01mT, 0.1mT AC Magnet Field: 50-200Hz
DC/AC: DC/AC Switch Unit: MT/Gs Unit Changing
Size: 150mm×70mm×30mm Weight: 500g
High Light:

mt test specimen

,

magnetic strenght meter

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter

 

Introduction

The Tesla meter is a special instrument used for inspecting & checking flux density, which is also one of the most universally devices in the field of magnetic measurement.

Model HGS10C digital Tesla meter is controlled by the SCM, which is suitable for handle operation. It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’s person. It is characterized by its wide measuring range, simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value, As mT or Gs unit of display can be change over, Measuring range of 200mT or 2000mT can be chose, and others that as resetting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours.

 

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 0

 

Application

  1. Magnetic field distribution of material surface
  2. Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
  3. Leakage Magnetic iron-surface

 

Main Technical Parameters

 

Rang: 0~200mT~2000mT

Accuracy: ±2%

Sensitivity: 0.01mT, 0.1mT

AC Magnet Field: 50-200Hz

Temperature of environment: 5℃-40℃

Relative humidity: 20%-80%(no condensation)

Power Supply: Battery 9V, constant DC power

Dimension: 150mm×70mm×30mm

Weight: N.W: 500g G.W:900g

Display: 4½ LCD

 

Shape of the device:

  1. Sensor Connecting
  2. LED Screen
  3. Zero/Reset Reading

 

Features

Shape of the device:

Peak/Real Value Switch

DC/AC Switch

Range Changing

mT/Gs Unit Changing

Power On/Off

External power supply socket

Sensor Connecting

LED Screen

Zero/Reset Reading

 

Operation request:

  1. Magnetic field distribution of material surface
  2. Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
  3. Leakage Magnetic iron-surface
  4. Do not use the instrument in unappropriate conditions.
  5. If you find the value of testing were error in the status ofmeasurement,

    you could loosened the handle of the probe to adjust the screw of the resistance tinily.

  6. If don’t ensure that the instrument is operated correctly described below, there would be error or mistake

  7. Don’t attempt to repair, or disassemble, and any reconstruct this instrument.

  8. Use only recommended power accessories.
  9. Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.
  10. Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.
  11. Do not allow hands or other objects with dirt to touch the probe.
  12. Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, so as to humidity, water, oil, rust air, vibration and others.

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 1Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 2Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 3

Contact Details
HUATEC GROUP CORPORATION

Tel: 0086 139 109 83110

Fax: 86-10-82916893

Send your inquiry directly to us (0 / 3000)